Clinical Pediatric Hematology-Oncology ; : 125-132, 2016.
Article in English | WPRIM | ID: wpr-788584

ABSTRACT

BACKGROUND: Flow cytometric analysis is the standard method for enumerating CD34+ stem cells in hematopoietic stem cell transplantation. However, it has some limitations such as expensive instrumentation, high reagent costs, and discrepancies between technicians and laboratories. We compared counts of total nucleated cells (TNCs) and CD34+ cells counts obtained from a flow cytometer with a newly-developed image-based microscopic cell counter (ADAM II) to evaluate the possibility of clinical application of the ADAM II.METHODS: We used 18 samples of circulating peripheral blood (PB) and waste tube fractions of peripheral blood stem cells (PBSCs) harvested by apheresis after G-CSF mobilization from adult volunteer donors. We assessed the reproducibility and linearity of the new procedure and compared the numbers of TNCs and viable CD34+ cells determined with the ADAM II and two different flow cytometers (FACSCalibur, FACSCanto II).RESULTS: Numbers of viable CD34+ cells determined with the ADAM II were accurate over the expected range; the intra-assay coefficient of variation was ≤19.8%. Linearity was also satisfactory (R²=0.99). TNC counts obtained with the ADAM II were highly correlated with those obtained with the FACSCalibur (R²>0.9841, P<0.0001) and FACSCanto II (R²>0.9620, P<0.0001), as were the numbers of viable CD34+ cells obtained with the ADAM II and the FACSCalibur and FACSCanto II (R²>0.9911, P<0.0001 and R²>0.9791, P<0.0001), respectively.CONCLUSION: The newly developed image-based microscopic cell counter (ADAM II) appears to be suitable for enumerating TNCs and viable CD34+ cells.


Subject(s)
Adult , Humans , Blood Component Removal , Cell Count , Granulocyte Colony-Stimulating Factor , Hematopoietic Stem Cell Transplantation , Methods , Stem Cells , Tissue Donors , Volunteers
2.
Clinical Pediatric Hematology-Oncology ; : 125-132, 2016.
Article in English | WPRIM | ID: wpr-30888

ABSTRACT

BACKGROUND: Flow cytometric analysis is the standard method for enumerating CD34+ stem cells in hematopoietic stem cell transplantation. However, it has some limitations such as expensive instrumentation, high reagent costs, and discrepancies between technicians and laboratories. We compared counts of total nucleated cells (TNCs) and CD34+ cells counts obtained from a flow cytometer with a newly-developed image-based microscopic cell counter (ADAM II) to evaluate the possibility of clinical application of the ADAM II. METHODS: We used 18 samples of circulating peripheral blood (PB) and waste tube fractions of peripheral blood stem cells (PBSCs) harvested by apheresis after G-CSF mobilization from adult volunteer donors. We assessed the reproducibility and linearity of the new procedure and compared the numbers of TNCs and viable CD34+ cells determined with the ADAM II and two different flow cytometers (FACSCalibur, FACSCanto II). RESULTS: Numbers of viable CD34+ cells determined with the ADAM II were accurate over the expected range; the intra-assay coefficient of variation was ≤19.8%. Linearity was also satisfactory (R²=0.99). TNC counts obtained with the ADAM II were highly correlated with those obtained with the FACSCalibur (R²>0.9841, P0.9620, P0.9911, P0.9791, P<0.0001), respectively. CONCLUSION: The newly developed image-based microscopic cell counter (ADAM II) appears to be suitable for enumerating TNCs and viable CD34+ cells.


Subject(s)
Adult , Humans , Blood Component Removal , Cell Count , Granulocyte Colony-Stimulating Factor , Hematopoietic Stem Cell Transplantation , Methods , Stem Cells , Tissue Donors , Volunteers
3.
Tuberculosis and Respiratory Diseases ; : 250-255, 1995.
Article in Korean | WPRIM | ID: wpr-196234

ABSTRACT

Diffuse tracheobronchial amyloidosis is an uncommon form of pulmonary involvement, and causes prolonged cough, dyspnea, wheezing and repeated development of pneumonia. We report a case of diffuse tracheobronchial amyloidosis in 58-year-old woman that was traeted by repeated electrocautry under flexible fiberoptic bronchoscopy. The patient had a long-standing history of dyspnea and was admitted due to resting dyspnea, which was aggravated to impending respiratory failure after diagnostic procedures. We applied repeated electrocautry to the endobronchial amyloid tumors and successfully reduced bronchial stenosis and the pateint didn\'t feel dyspnea. We suppose that, in certain cases of tracheobronchial amyloidosis patients, endobronchial electrocautry would be a helpful procedure.


Subject(s)
Female , Humans , Middle Aged , Amyloid , Amyloidosis , Bronchoscopy , Constriction, Pathologic , Cough , Dyspnea , Pneumonia , Respiratory Insufficiency , Respiratory Sounds